Max-Planck-Institut für extraterrestrische Physik Effective Area |
|
| | ||
|
|
Next: Spatial Variations in Effective Up: 6.2 Performance of the Previous: 6.2 Performance of the
Effective Area
Figure 6.3 shows the on-axis effective area of the complete WFC for each filter at the time of launch. These curves have been derived from calibration data acquired both on the ground and in-orbit. The systematic uncertainties are probably of order 10% for the S1 and S2 filters and 30% for the P1 and P2. Note that some of the available WFC filters have a secondary transmission band in the far-ultraviolet. Although the far-UV transmission is much weaker than that in the primary EUV bands, problems may potentially arise when observing objects that have a particularly strong far-UV component in their spectrum.
During a period of attitude control failure and uncontrolled pointing on 1991 January 25-26 the ROSAT WFC suffered a severe loss in sensitivity. This is thought to be due to contamination of the detector photocathodes, although the source of the contamination is not known. For some time after this event the efficiency of the instrument continued to drop reaching a minimum around June 1991. It then started to improve slowly but reached a plateau in July 1992 and now seems to have stabilised. Efficiency history curves have been constructed for all the WFC filters from periodic calibration observations of DA white dwarfs; these curves can be used to compare WFC observations at different epochs (Fig. 6.4).
Next: Spatial Variations in Effective Up: 6.2 Performance of the Previous: 6.2 Performance of the If you have problems/suggestions please send mail to xray-info @ mpe . mpg . de | |