Spatial Variations in Effective Area

The reflectivity of the mirror assembly decreases with increasing off-axis angle, dropping linearly to 67% of its on-axis value at tex2html_wrap_inline14217 off-axis.   Beyond this the vignetting function is dominated by geometric baffling. Rejection of scattered flux from bright sources outside the field of view is good. Less than 0.5% and 0.01% of the source flux is detected for sources tex2html_wrap_inline14219 off-axis and tex2html_wrap_inline14221 off-axis respectively.

In addition to the vignetting intrinsic to the mirror assembly, the quantum efficiency of the WFC microchannel plate detectors vary as a function of position of a source within the field of view, probably due to variations in the quantum efficiency of the CsI coating deposited on the face of the MCP.   This effect has been calibrated using the survey observation of the bright white dwarf HZ 43 by binning the source photons into detector coordinates.  Figure 6.5 shows the combined effects of the spatial variations in the detector efficiency and the mirror vignetting.    

   figure3962
Figure 6.6: On-axis encircled energy function as measured at energies of 20, 69 and tex2html_wrap_inline14223 .

   figure3969
Figure 6.7: In-orbit WFC encircled energy function as measured on-axis and at tex2html_wrap_inline14227 and tex2html_wrap_inline14229 off-axis ( tex2html_wrap_inline14231 ).

   figure3977
Figure 6.8: Radial response profile derived from an on-axis observation of the bright white dwarf HZ 43 during the Performance Verification phase of the mission. The exposure time is tex2html_wrap_inline14233 , and the S2B filter was used for the observation. The dashed line shows the level of the background in the observation.