Climate Chamber

In the climatic Chamber, assemblies can be tested under thermal and climatic stresses.

The Chamber is also used to anneal components, thermal zykeln or auxiliary heating.

Technical data

Feutron GmbH

Test chamber volume:

600 DM ³

Test area  L x W x H:

770 x 1020 x 745 (in mm)

Temperature range:

- 75 ... 180 ° C

Rate of change:

+ 3 K/min
- 3 K/min
- 0.6 K/min (during active air conditioner)

Moisture Range:

10 ... 95
% r.F.

Temperature monitoring:

Hybrid Recorder with 10 free channels

Go to Editor View